C a l i b r a t i n g
t h e s y s t e m
2 8
To start the calibration procedure
Either:
Press Next on the last option of configuring settings; see page
24.
Or:
Press On/Off to put the digital surround controller into standby.
Press
More.
If the product is locked the display shows:
5NLOCK6ERSION
Press Unlock.
The display shows:
,OCK#ALIB6ERSION )2 7IZARD
Press Calib.
The displays shows Please wait….
After a few seconds the display shows the first calibration test:
Left Level +0.0dB
ìî ïñ öõú óòô
Press More for help
For more detailed information about this and the other calibration
tests see the following sections.
To exit from the calibration procedure
You can exit from the calibration procedure at any time, and any
parameters you have set will be retained:
Press
On/Off.
To complete the calibration procedure
When you reach the end of the calibration procedure the following
display confirms that you have completed the calibration of the
system:
Back Next Restart
Calibration complete.
Press Restart to restart the calibration procedure, or Next to
complete the wizard.
The display shows:
RestartBack Exit
Press More for help
Wizard complete
Either:
Press Exit to return to standby.
Or:
Press Restart to return to stage 1; see page 18.